[. . . ] Since this will impose a network load, we recommend that you use the "R Series Information" dialog box to set the connection status to Disconnect. ■ Setup The setup workflow is shown below. Installing the R Remote ↓ Settings on the R series units ↓ Connect the computer and R series units ↓ Power-on the R series units ↓ Accessing the Control Panel ↓ TCP/IP Settings ↓ Use Dante Controller or the CL series console to specify the routing R Remote Operation Manual 3 Installing the R Remote The installation procedure is as follows. After decompressing the downloaded file, double-click “setup. exe” in the decompressed file location. ・ If the computer you’re using does not have Bonjour installed, a screen asking you to install Bonjour will appear during the installation. [. . . ] The “Local Area Connection Status” dialog box will be displayed. ・The “User Account Control” dialog box may appear. ・If the “Local Area Connection properties” dialog box appears, skip ahead to step 4. 3. Click [Properties]. 「The “Local Area Connection properties” dialog box will be displayed. The “User Account Control” dialog box may appear. 5. Select [Internet Protocol Version 4(TCP/IPv4)], then click [Properties]. The “Internet Protocol Version 4(TCP/IPv4) Protocol” dialog box will be displayed. Click [Obtain an IP address automatically]. 6. Click [OK]. R Remote Operation Manual 7 Use Dante Controller or the CL series console to specify the routing You'll use Dante Controller or the CL series console to specify the routing. If you're using Dante Controller to specify the routing, refer to "Dante Controller User’s Guide. " If you're using a CL series console to specify the routing, refer to "CL5/CL3/CL1 Reference Manual. " This completes the setup. R Remote Operation Manual 8 ■Operating R Remote When you start R Remote, the "Network Setup" dialog box may appear, allowing you to select the computer's network card that will be used for communication with the R series units. If this appears, click the network card that is connected to the R series unit, and then click the [Apply] button. When you're finished using R Remote, click the [x] button in the upper right to close the application. For R Remote for Windows 8 / Windows 8. 1, depending upon user access privileges, the software's "Tile(icon)" may not appear on the "Start screen". In such cases, you can find the software icon in "Apps" by the following steps: 1. Click "All apps" button at the bottom right side of Start screen. Menu bar The commands that can be executed by R Remote can be found here, grouped by category. Click here to see a list of commands. Menu [File] Command [Open] Summary Opens a previously-saved file (RRM format). If you open the file when R series units are connected, the settings will be applied to the R series units. Be aware that if a CL series console is also connected, its settings will be overwritten. Dialog box that appears “Open File” dialog box [Save As] Saves the file. It will have a file name extension of RRM, and will be usable only by R Remote. “Save File” dialog box [Network Setup] Selects the computer’s network adapter that will be used to communicate with the R series. ”Network Setup” dialog box ”R Series Information” dialog box [R Series Information] Displays information about the R series units that are connected. You can also disconnect R series units that you don't want to control from R Remote. [About] [About R Remote] Displays details such as the software version of R Remote. “About R Remote” dialog box R Remote Operation Manual 9 Main screen Here you can make settings for the HA of the R series units. ① Display select buttons Click one of these buttons to view the corresponding R series unit at the right. Up to two instances of R Remote can be simultaneously connected to an R series unit. For example, this would allow the main operator to operate the CL console while two assistants make small adjustments in different locations. If you hold down this button, all indicators of the corresponding R series unit will blink, allowing you to identify that unit. If the R series unit is not connected, the Rio3224-D settings screen is shown, and the indication "VIRTUAL" is shown below the button. ② ID/Name indication Shows the ID number and name of the R series unit. [. . . ] If the “User Account Control” dialog box appears, click [Continue] or [Yes]. R Remote Operation Manual 15 ■ Troubleshooting Problem R series unit is not detected Possible cause The R series unit's power switch is not on The R series unit's DIP switch settings are incorrect Make the same settings as shown in one of the DIP switch setting examples of "Settings on the R series unit". The UNIT ID of the R series unit is set to something other than 1 through 8 The cables are not connected properly If the right side of the [SYNC] indicator is blinking, a cable is broken or not connected correctly. If you're using REDUNDANT mode, connect to the network switch that is connected to the [PRIMARY] connector. TCP/IP settings are incorrect Set the computer's TCP/IP setting to [Obtain IP address automatically (O)]. [. . . ]